> INPUT CHARACTERISTICS:
VOLTAGE: 100 ~ 240 VAC (WITH กำ10% TOLERANCE)
FREQUENCY: 47 - 63 Hz
INPUT CURRENT: 2.5A / 1.5A PER UNIT (PARALLEL) 7.0A / 4.0A (ONE POWER)
INRUSH CURRENT:
65A MAX. FOR 110 VAC
125A MAX. FOR 220VAC
> SPECIFICATION
TEMPERATURE RANGE : OPERATING 0oC --- 40oC, STORAGE -20oC --- 80oC
TRANSIENT RESPONSE: OUTPUT VOLTAGE RETURNS IN LESS THAN 1 ms MAX. FOLLOWING A 50% LOAD CHANGE
HOLD UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT VOLTAGE
DIELECTRIC WITHSTAND: INPUT / OUTPUT 1800 VAC FOR 1 MINUTE
INPUT TO FRAME GROUND 1800 VAC FOR 1 MINUTE
HUMIDITY: 10 ~ 90% RH
EFFICIENCY: 68% TYPICAL, AT 115V, FULL LOAD
POWER GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms
OVER LOAD PROTECTION: 110 ~ 150% MAX.
OVER VOLTAGE PROTECTION:
+5V5.7V ~ 6.5V, 3.3V3.9V ~ 4.3V, +12V13.6V ~ 15V
OVER CURRENT PROTECTION:
+5V44A ~ 60A, +12V29.7A ~ 40.5A, +3.3V33A ~ 45A
POWER FACTOR CORRECTOR: MEET IEC-1000-302 CLASSD (ACTIVE PFC)
ALARM METHOD: 1. AUDIO ALARM, 2. FAULT LED, 3. POWER DEFECTIVE, 4. AC IN DEFECTIVE, 5. EACH POWER MODULE'S IN SIGAL
FCC CLASS B, CISPR22 CLASS B
SAFETY: UL / CSA / TUV APPROVAL
HOT-SWAPPABLE / HOT-PLUGGABLE CAPABILITY
DIMENSION: REFER TO THE DRAWING
REDUNDANCY: BALANCE SHARE LOAD METHOD
REMOTE ON/OFF: OPERATE BY A REMOTE (SELV) SIGNAL
5VSB STANDBY VOLTAGE: A LOW CURRENT CONTINUOUS 2A SOURCE AT +5V, ALWAYS ENABLE, CAN NOT BE REMOTE OFF

> INPUT CHARACTERISTICS:
OUTPUT VOLTAGE
OUTPUT CURRENT
REGULATION
OUTPUT
RIPPLE & NOISE
MAX.[P-P]
MIN.(A)
MAX.(A)
LOAD
LINE
+5V
5.0
40
± 5%
± 1%
60mV
+12V
0.0
0.8
± 5%
± 1%
100mV
-5V
2.5
27
± 5%
± 1%
100mV
-12V
0.0
1.0
± 6%
± 1%
100mV
+3.3V
0.0
30
± 5%
± 1%
60mV
+5VSB
0.0
2.0
± 7%
± 1%
60mV
 
REMARKS:
TOTAL CURRENT OF +5V AND +3.3V : 50A

BACK  /  HOME