INPUT CHARACTERISTICS: |
|
|
VOLTAGE:
100 ~ 240 VAC (WITH กำ10% TOLERANCE) |
|
|
FREQUENCY:
47 - 63 Hz |
|
|
INPUT
CURRENT: 2.5A / 1.5A PER UNIT (PARALLEL) 7.0A / 4.0A (ONE
POWER) |
|
|
INRUSH
CURRENT:
65A MAX. FOR 110 VAC
125A MAX. FOR 220VAC |
| >
SPECIFICATION |
|
|
TEMPERATURE
RANGE : OPERATING 0oC --- 40oC,
STORAGE -20oC --- 80oC |
|
|
TRANSIENT
RESPONSE: OUTPUT VOLTAGE RETURNS IN LESS THAN 1 ms MAX.
FOLLOWING A 50% LOAD CHANGE |
|
|
HOLD
UP TIME: 16 ms MINIMUM AT FULL LOAD & NORMAL INPUT
VOLTAGE |
|
|
DIELECTRIC
WITHSTAND: INPUT / OUTPUT 1800 VAC FOR 1 MINUTE
INPUT TO FRAME GROUND 1800 VAC FOR 1 MINUTE |
|
|
HUMIDITY:
10 ~ 90% RH |
|
|
EFFICIENCY:
68% TYPICAL, AT 115V, FULL LOAD |
|
|
POWER
GOOD SIGNAL: ON DELAY 100 ms TO 500 ms, OFF DELAY 1 ms |
|
|
OVER
LOAD PROTECTION: 110 ~ 150% MAX. |
|
|
OVER
VOLTAGE PROTECTION:
+5V 5.7V
~ 6.5V, 3.3V 3.9V
~ 4.3V, +12V 13.6V
~ 15V |
|
|
OVER
CURRENT PROTECTION:
+5V 44A
~ 60A, +12V 29.7A
~ 40.5A, +3.3V 33A
~ 45A |
|
|
POWER
FACTOR CORRECTOR: MEET IEC-1000-302 CLASSD (ACTIVE PFC) |
|
|
ALARM
METHOD: 1. AUDIO ALARM, 2. FAULT LED, 3. POWER DEFECTIVE,
4. AC IN DEFECTIVE, 5. EACH POWER MODULE'S IN SIGAL |
|
|
FCC
CLASS B, CISPR22 CLASS B |
|
|
SAFETY:
UL / CSA / TUV APPROVAL |
|
|
HOT-SWAPPABLE
/ HOT-PLUGGABLE CAPABILITY |
|
|
DIMENSION:
REFER TO THE DRAWING |
|
|
REDUNDANCY:
BALANCE SHARE LOAD METHOD |
|
|
REMOTE
ON/OFF: OPERATE BY A REMOTE (SELV) SIGNAL |
|
|
5VSB
STANDBY VOLTAGE: A LOW CURRENT CONTINUOUS 2A SOURCE AT
+5V, ALWAYS ENABLE, CAN NOT BE REMOTE OFF |